Technical Data
Boost
In Rotary switch mode: When the optocoupler is energized,
the MCD increases the run and stop current by 30%.
Boost current is programmable in the ServiceBus mode.
Activation
When the optocoupler is energized, the power stage is ready.
Reset
When the input optocoupler is energized, all error messages
are reset and the control circuit is initialized.
Output
Optically insulated from the motor voltage, type open-
collector
I
max
= 20 mA, U
max
= 30 V, P
total
= 300 mW,
UCE
sat
at 20 mA < 1 V
Error
The output opens in case of the following error signals: short
circuit, overcurrent, undervoltage, overvoltage, overheat.
To avoid damages, the drive is deactivated at the same time.
Ambient
temperatures
Operation: 4 to +40 °C *)
Storage: –25 to +55 °C
Transport: –25 to +85 °C
*) We recommend an additional cooling in case of higher
operation temperatures.
Ambient standards
EN 50178
Electronic equipment for use in power
installations
degree of pollution 2 should be observed
EN 61000-6-2
(EN 55011)
Immunity for industrial environments
class A
EN 61000-6-3
(EN 55022)
Emission standard for industrial
environments class B
A line filter with 20 dB damping is
necessary in the range from 0.15 to 1 MHz
(f.ex. Corcom 5VR1).
Remark:
If PS 5, phytron’s power supply
unit, is used, any line filter isn’t required.
EN 61000-6-4
Emission standard for industrial
environments class A
EN 61000-3-2
Electromagnetic compatibility (EMC)
Minimum free space
The MCD should be built-in vertically to ensure convection.
Minimum free space to other devices: 30 mm
Minimum free space below and above the device: 100 mm
Required free space for cables and connectors:
about 30 mm at the MCD front panel