phytron
41
MA 2102-A005 GB
Instruction
code
Parameter
name
Type Value
Description
De-
fault
values
M
Step width
R/W 0 to 12
0= 1/1
1= 1/2
2= 1/4
3= 1/5
4= 1/8
5=1/10
6=1/16
7=1/20
8=1/32
9=1/64
10=1/128
11=1/256
12=1/512 step
9
O Output
logic
level Error
(open
collector)
R/W 0 or 1
Define output error logic level:
0 = Transistor opened
1 = Transistor locks
0
P Extra
parameters
R/W
X
1st byte of the instructions ‚Extra
parameters’, to define security
functions
See chap. 9.2.1
–
Q
Error inquiry
R
0 to 3
0=no error
1=undervoltage/overvoltage
2=overtemperature
3=overcurrent
–
R
Run current
R/W 0 to 63
Run current values from
0 to 6.3 A
r.m.s.
S
Stop current
R/W 0 to 63
Stop current values from
0 to 6.3 A
r.m.s.
T
Delay time
R/W 0 to 15
0= 1
1= 2
2= 4
3= 6
4= 8
5=10
6=12
7=14
8= 16
9= 20
10= 40
11= 60
12= 100
13= 200
14= 500
15=1000 ms
10
U
*
Power stage
deactivation
R/W 0 or 1
0 = activated
1 = deactivated
1
*
)
Remark for ServiceBus mode: Please deactivate the power stage only by U=0, if it isn’t still deactivated by
the input Activation (connector X3).