Remark:
If
only one
setting switch (S2, S3 or S4) is set to ‘0’ in the ServiceBus mode, the MCD will
be deactivated.
Operating mode: Bus mode exclusive
This operating mode is a special ServiceBus mode with safety locking. In Bus mode
exclusive all settings at the rotary switches are ignored.
Important:
•
In setting switch mode the rotary switch adjustments are only accepted after a Reset
signal.
•
Settings in the power stage also can be changed in setting switch mode by
ServiceBus-Comm
®
. After Reset (and then only) the settings of the rotary switches are
read.
1.5.1 Rotary
Switch
Mode
Run and stop current (I
Run
, I
Stop
), step resolution and preferential motor direction (STEP) to
15 positions (1…F), the device address (Address) to 16 positions (0…F) can be set by the
four setting switches at the front side.
9
MA 2102-A005 GB
Fig. 6: Rotary switch mode – parameter setting by rotary switches