4.1
Preparing the Target Hardware to Communicate with
ROM Monitor
•
Ensure that the target hardware is properly connected to the
host-PC and a power supply.
•
Reset the target hardware and force it into Flash programming
mode by simultaneously pressing the Reset (S1) and Boot (S2)
buttons on the Development Board and then releasing first the
Reset and, two or three seconds later, the Boot button.
•
Start FlashTools98 for Windows.
•
At the Serial Interface tab of the FlashTools98 tabsheet, specify
the proper serial port and transmission speed for communication
between host-PC and target hardware and click the Connect button
to establish connection to the target hardware.
•
Returning to the FlashTools98 tabsheet, choose the Bank Utilities
tab, highlight Banks #1 and click on the Erase Bank(s) button.
•
Next choose the File Download tab and click on the File Open
button.
•
Download the file load51.hex from the Tools folder
C:\PHYBasic\pC-P87C591\Tools\Raisonance\Loader
(default location).
The PHYTEC Spectrum CD-ROM also contains the loadxa.hex
monitor file. This version is made for XA-compatible phyCORE
modules. Please refer to readme files within the Loader directory
for details.
•
Click on the Download button and view the download procedure
in the status window.
If download is successful, the loader kernel has been programmed
into the external Flash memory. The target hardware is now prepared
to communicate with the Raisonance RIDE debugging tools installed
on the host-PC.
Summary of Contents for phyCORE-P87C591
Page 14: ...phyCORE P87C591 QuickStart Instructions 10 PHYTEC Me technik GmbH 2002 L 586e_2...
Page 36: ...phyCORE P87C591 QuickStart Instructions 32 PHYTEC Me technik GmbH 2002 L 586e_2...
Page 52: ...phyCORE P87C591 QuickStart Instructions 48 PHYTEC Me technik GmbH 2002 L 586e_2...
Page 84: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 586e_2 Printed in Germany...