8-2
Philips Communication, Security & Imaging
Electrical
Voltage and Power
All models
100-240 VAC; 0.7-0.3A, 50/60Hz
Video
Video standard:
PAL/NTSC auto-detect
Resolution:
720 x 576 PAL - 720 x 484 NTSC
AGC:
Automatic adjustment or manual adjustment of gain for
each video input
Digital Zoom:
2 or 4 times
Compression: WAVELET
Inputs:
composite video 0.5-2Vpp, 75 ohm, automatic termination
Outputs:
1Vpp, 75 ohm, sync 0.3 V ± 10%
Alarm Handling:
Inputs:
6, 9 or 16 configurable NO/NC
max. input voltage 40 VDC
Outputs:
4 relay outputs, configurable NO/NC
max. rated 30 VAC - 40 VDC - 0.5A continuous -10VA
Control
RS232:
Output signals according EIA/TIA-232-F
max. input voltage ±25V
Keyboard input:
Conform RS485, max. signal voltage ±12V,
supply 11V-12.6V at max. 400mA
Keyboard output:
Conform RS485, max. signal voltage ±12V
Bi-Phase:
Impedance 128 ohm, max.
overvoltage protection ±40V,
max. cable length 1.5km
Connectors
Video inputs:
6, 9 or 16 looping BNC, auto-terminating
Ethernet:
RJ45 shielded, 10/100 BaseT according IEEE802.3
Monitors:
BNC (2), MON-A multiscreen, MON-B spot/alarm
Alarm connectors:
Screw terminal input
Bi-Phase: Screw
terminal
output
RS232: DB9
male
Keyboard input:
RJ11 (6-pin)
Keyboard output:
RJ11 (4-pin), conform RS485, 30 units max.
SCSI:
HD 50-pin, max. 7 connected ultra SCSI devices,
20Mbytes/sec, terminated internally
Summary of Contents for Divar
Page 1: ...DIVAR DIGITAL VERSATILE RECORDER Installation Manual www philipscsi com ...
Page 40: ...Hardware setup 4 10 Philips Communication Security Imaging ...
Page 62: ...Using the Configuration Tool 6 8 Philips Communication Security Imaging ...
Page 70: ...Menu default values 7 8 Philips Communication Security Imaging ...