Internal PM-48V-INT or PM-40V-INT line power module installation
119
SmartNode 1000 and 2000 Series Getting Started Guide
8 • Line power module installation
SmartNode 2400 line power module installation
The 40V line power module is mounted inside the SmartNode 2400, next to the existing 12V power supply.
You should not move the 12V power supply module from its installed location (see
figure 82
for 12V power
supply location).
Figure 82. Internal 40V line power module and 12V power supply module locations in
a SmartNode 2400 (AC version only)
Do not install a 48V line power module into the SmartNode 2400!
The 40V line power module can not be installed in a SmartNode
Model SN2400/48.
CAUTION
IMPORTANT
SmartNode 2400
Motherboard
12V socket
Rear of chassis
Existing connection
40V 4-strand cable
Plastic stud
mount
Power cable
for 40V power
supply
AC power socket
Capacitor on 40V line power module
is labeled
ZWS30-36
Socket
for 40V power
supply
40V socket
Capacitor on existing 12V power supply
is labeled ZWS30-12
Location of
plastic foil
Screw
mounting
40V power supply