3028
Turbo
Statistical Multiplexer
2-68
154001UA
The terminal displays:
To change the EIA output options:
TYPE:
n (n = the number of the output to change)
PRESS:
RETURN
The display will have an
@
symbol after the
ON
or
OFF
indicating the change
was forced by the operator.
The Main Menu is displayed after an EIA output is changed. To verify that the
EIA output was updated, the parameter must be selected again.
2 0 3 1 2 -4 2
CHANNEL n STATUS:
EIA OUTPUTS: EIA INPUTS: STATUS:
1. CTS: OFF DSRS: OFF LOCAL LOOPBACK: OFF
2. RI: OFF BO: OFF REMOTE LOOPBACK: OFF
3. DCD: OFF RTS: OFF DATA ACTIVITY: NO
4. DSR: OFF DTR: OFF FLOW CONTROL: OFF
REV FL CONTROL: OFF
(ENTER 1-4 <CR> TO SET OR RELEASE OUTPUT SIGNAL, OR <CR> TO EXIT.):
Remote Signon
Remote Signon
Remote Signon
Remote Signon
Remote Signon
The
REMOTE SIGNON
command is used in a point-to-point application with a
3028
Turbo (CTS 2031 Turbo)
multiplexer at each end. It allows access to the
supervisory functions at the remote end. Any command that is available on the
local supervisory facility can be accessed except Remote Signon, Link Reset, and
Link Loopback. When in remote supervisor mode , the
LOGOFF
command and the
REMOTE SIGNOFF
command will both cause the remote supervisor to be signed
off.
Front Panel Access
From the
COMMAND MODE
display:
Note
Ensure that supervisory mode is enabled at
the local and remote ends before attempting
to sign on through a standard channel port.
Note
A CHANNEL RESET or System Reset will
remove a forced condition. A power failure
will not reset the forced condition.