3028 Turbo Statistical Multiplexer
154001UA
H-2
MUL
MUL
MUL
MUL
MULTIPLEXER
TIPLEXER
TIPLEXER
TIPLEXER
TIPLEXER
CONFIGURA
CONFIGURA
CONFIGURA
CONFIGURA
CONFIGURATION
TION
TION
TION
TION
The multiplexer card for the 3028 Turbo (CTS 2031 Turbo) is illustrated in Figure
H-2. The strapping options for this PCB are discussed in the following para-
graphs.
Put switch 1, position 1 through 4, in the
OFF
OFF
OFF
OFF
OFF
position. It is unused.
JP11 is the Watch Dog Timer and is
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
.
JP10 is the Signal Ground to Chassis Ground connect. To connect chassis and
signal ground install the jumper. Factory default is not connected.
JP12, JP13 and JP14 are used for factory test only and must be installed for opera-
tion of the 2031
Turbo
.
JP1 - JP8 are to enable or disable External Receive Clocks (pin 18). To use the
External Receive Clock Option install the jumper on the A side of the appropriate
port. Jumpers on A is factory default
JP2 (1A & 1B) go to Port 1
JP1 (2A & 2B) go to Port 2
JP4 (3A & 3B) go to Port 3
JP3 (4A & 4B) go to Port 4
JP6 (5A & 5B) go to Port 5
JP5 (6A & 6B) go to Port 6
JP8 (7A & 7B) go to Port 7
JP7 (8A & 8B) go to Port 8
JP9 selects the TX Clock Source for the Composite Port. Select 9A for clock source
from Pin 15 (TxC), select 9B for clock source from Pin 24 (ETxC). Factory default is
9A.
F1 and F2 provide over current protection for the 2031
Turbo
. When the Power
Selector switch is set for 115V, replace blown fuses with 0.16ASB 250V. When the
Power Selector switch is set for 230V, replace blown fuses with 0.08ASB 250V. To
replace the fuse, remove the power cord from the rear of the unit, then turn the fuse
cap a quarter turn to the right. Remove the cap with the fuse attached and replace
the fuse. Reverse the process to reinstall the new fuse. Reattach the power cord to
the rear of the unit.
The 3028 Turbo (CTS 2031 Turbo) is factory set to the proper line voltage for the
area it is shipped to from the factory. In the event it is necessary to install the unit
in an area with a line voltage other than the voltage initially set at the factory,
remove the line cord and move the Power Selector switch to the appropriate setting.
Never remove the cover without removing the line cord first.
The Krypto reset pulse is 150ms in duration and occurs every 4, 8, 12 or 16 seconds
as selected by jumpers J15 and J16 and the table below. (See page 1-8)
JP16 JP15
Time Delay
ON
ON
4 Seconds
OFF
ON
8 Seconds
ON
OFF 12 Seconds
OFF
OFF 16 Seconds