2. Operation of the 3028
Turbo
Multiplexer
154001UA
2-49
Supervisory
Supervisory
Supervisory
Supervisory
Supervisory
Parameters
Parameters
Parameters
Parameters
Parameters
The
SUPERVISORY PARAMETERS
command is used to examine and change
the parameters of the supervisory port. This port does not take part in connec-
tions, therefore , not all of the channel parameters are relevant. The supervisory
parameters are not copied when the
COPY PARAMETERS
command is used.
Refer to Table 2-5 for the supervisory parameters.
Table 2-5. Supervisory Commands and Options
Table 2-5. Supervisory Commands and Options
Table 2-5. Supervisory Commands and Options
Table 2-5. Supervisory Commands and Options
Table 2-5. Supervisory Commands and Options
COMMAND
DEFAULT
OPTIONS
SPEED
9600
50, 75, 110, 134, 150, 300, 600,
1200, 1800, 2000, 2400, 3600,
4800, 7200, 9600 or AUTOB
DATA BITS
8
8 or 7
STOP BITS
2
1, 1.5, 2
PARITY
NONE/ODD
NONE/ODD, NONE/EVEN,
ODD, EVEN, NONE/MARK,
NONE/SPACE
RV FL CTL
(Reverse Flow
Control)
NONE
DC3/DC1, DC2/DC1, DC4/DC2
or NONE
NOTE: These are the only supported supervisory parameters and options.
Front Panel Access
Supervisory parameters are set using the
CHANNEL PARAMETERS
and
selecting the supervisor channel for configuration.
2 0 3 1 2 -2 7
(ENTER 1-3 <CR> TO CHANGE. <CR> TO RETAIN OLD SETTING.):
LINK CLOCK RATE: CURRENTLY: 9600
1:
3:
19200
7200
5: 3600
7:
1200
2:
4:
9600
4800
6: 2400
The terminal displays:
TYPE:
n (n = clock rate option number)
PRESS:
RETURN
The multiplexer updates the link clock rate and returns the
LINK PARAM-
ETERS
menu. If the
RETURN
key is pressed without entering a clock rate
option, the Main Menu is returned.