3028
Turbo
Statistical Multiplexer
2-4
154001UA
PUSH BUTTON
DESCRIPTION
NEXT
This push button allows entry into COMMAND mode (refer
to COMMAND MODE section) when the start-up message
is displayed or the device is in MONITOR mode (refer to
MONITOR MODE section).
In COMMAND mode (COMMAND MODE displayed on the
first line of the LCD) this push button moves to the next
command. If the LCD displays a parameter (parameter
displayed on the first line of the LCD) this push button
causes the next parameter to appear. This push button
does not update the parameter.
LAST
In COMMAND mode this push button is used to move to
the previous command, parameter or option depending on
the level of operation at any given time. This push button
does not update the parameter.
SELECT
This push button is used in COMMAND mode to enter the
displayed parameter or update use of the selected option.
MON/CLR
This push button is used in COMMAND mode to exit a
parameter without making changes and return to the
COMMAND MODE / CHNL PARAMETERS display.
If you are already at the command prompt, this push button
logs off as supervisor and enters MONITOR mode. If this
push button is pressed while in MONITOR mode, the LCD
will display:
This display will remain until the NEXT push button is
pressed to enter COMMAND mode or the MON/CLR push
The multiplexer has four LED displays on the front panel. Their functions are
described in Table 2-2.
Table 2-1. Front Panel Push Button Descriptions
Table 2-1. Front Panel Push Button Descriptions
Table 2-1. Front Panel Push Button Descriptions
Table 2-1. Front Panel Push Button Descriptions
Table 2-1. Front Panel Push Button Descriptions
Table 2-2. Panel LED Descriptions
Table 2-2. Panel LED Descriptions
Table 2-2. Panel LED Descriptions
Table 2-2. Panel LED Descriptions
Table 2-2. Panel LED Descriptions
LED
DESCRIPTION
POWER
This LED indicates that the power supply is operating. If
this LED does not light and the system is plugged in, a
LINK DOWN
This LED, when lit, indicates that the communication link
has failed, when flashing, indicates a loopback state.
FLOW CONTROL
This LED is turned on when buffer usage reaches 65%
and is turned off when the total buffer usage drops below
45%. These limits indicate the thresholds for potentially
invoking or releasing channel flow control signals.
DATA LOSS
This LED is lit for ten seconds when data is lost or when
the aggregate input limit of 76.8Kbps has been exceeded.