Projective Capacitance (PCAP) Touchscreen Chemical Resistance Table
Test for Transmittance Due to Haze, Corrosion or Damage
Chemical Applied
Condition of Glass Prior
Condition of Glass After
Judgement
Acetic Acid
No damage on surface
No damage on surface
PASS
Acetone
No damage on surface
No damage on surface
PASS
Alcohol 95%
No damage on surface
No damage on surface
PASS
Vaseline
No damage on surface
No damage on surface
PASS
Ammonia
No damage on surface
No damage on surface
PASS
Lanoline
No damage on surface
No damage on surface
PASS
Salt Solution
No damage on surface
No damage on surface
PASS
Cold Cream
No damage on surface
No damage on surface
PASS
Cidex
No damage on surface
No damage on surface
PASS
Gasoline
No damage on surface
No damage on surface
PASS
Glycerine
No damage on surface
No damage on surface
PASS
Green Soap Water
No damage on surface
No damage on surface
PASS
Incidin Liquid
No damage on surface
No damage on surface
PASS
Incidin Plus
No damage on surface
No damage on surface
PASS
Windex
No damage on surface
No damage on surface
PASS
Isopropyl Alcohol
No damage on surface
No damage on surface
PASS
Kerosene
No damage on surface
No damage on surface
PASS
Methanol
No damage on surface
No damage on surface
PASS
Parafin Oil
No damage on surface
No damage on surface
PASS
Propanol
No damage on surface
No damage on surface
PASS
Toluene
No damage on surface
No damage on surface
PASS
Hydrochloric Acid
No damage on surface
No damage on surface
PASS
Nitric Acid
No damage on surface
No damage on surface
PASS
Sulfuric Acid
No damage on surface
No damage on surface
PASS
Caustic Soda
No damage on surface
No damage on surface
PASS
Ethyl Ether
No damage on surface
No damage on surface
PASS
Glutaraldehyde
No damage on surface
No damage on surface
PASS
Test method: Samples of touchscreens were tested as follows:
1.
Observe condition of test sample prior to testing.
2.
Apply 10 c.c. of agent to test sample and cover with dust free cloth.
3.
Dwell at 25
ºC
for 24 hours.
4.
After test period, wipe agent from target area with clean cloth.
5.
Observe condition of test sample after testing.
6.
Any damage or discoloration is not accepted.
Summary of Contents for PowerStation XT Series
Page 12: ......
Page 13: ...CHAPTER 1 Product Overview ...
Page 33: ...CHAPTER 2 Installation ...
Page 47: ...CHAPTER 3 Software ...
Page 53: ...As you create panels they will now show what will appear on the IX hardware ...
Page 55: ......
Page 59: ...CHAPTER 4 BIOS Setup ...
Page 79: ...CHAPTER 5 Troubleshooting ...
Page 88: ......
Page 89: ...APPENDIX A XT IX PCA PowerStation Specifications ...
Page 97: ...Figure A 5 10 1 Physical Dimensions and Panel Cutout Figure A 6 10 1 Rear View ...
Page 99: ...Figure A 9 21 5 Physical Dimensions and Panel Cutout Figure A 10 21 5 Rear View ...