![Parker PowerStation XT Series User Manual Download Page 93](http://html1.mh-extra.com/html/parker/powerstation-xt-series/powerstation-xt-series_user-manual_3724983093.webp)
Touchscreen Chemical Resistance Specifications
Resistive Touchscreen Chemical Resistance Table
Test for Transmittance Due to Haze
Chemical Applied
Transmissivity Before
Dwell Time
Transmissivity After
Window Cleaners
81.6%
1 hour @ 22 ~ 28ºC
81.6%
Alcohol
81.4%
1 hour @ 22 ~ 28ºC
81.3%
Toluene
81.4%
1 hour @ 22 ~ 28ºC
81.1%
Oil
81.1%
1 hour @ 22 ~ 28ºC
81.4%
Phenol
81.3%
1 hour @ 22 ~ 28ºC
81.3%
Bleach
81.3%
1 hour @ 22 ~ 28ºC
81.6%
Glycol
81.6%
1 hour @ 22 ~ 28ºC
81.7%
Isopropanol
81.9%
1 hour @ 22 ~ 28ºC
81.9%
Glutaraldehyde
81.9%
1 hour @ 22 ~ 28ºC
81.6%
Test method: Samples of touchscreens were tested as follows:
1.
Measurement of spectral transmissivity in target areas before application of chemical agent.
2.
Apply agent to target area.
3.
Dwell for 1 hour at target temperature.
4.
After test period, wipe agent from target area with clean cloth.
5.
Measure the target area again to determine any changes in transmittance due to haze.
Summary of Contents for PowerStation XT Series
Page 12: ......
Page 13: ...CHAPTER 1 Product Overview ...
Page 33: ...CHAPTER 2 Installation ...
Page 47: ...CHAPTER 3 Software ...
Page 53: ...As you create panels they will now show what will appear on the IX hardware ...
Page 55: ......
Page 59: ...CHAPTER 4 BIOS Setup ...
Page 79: ...CHAPTER 5 Troubleshooting ...
Page 88: ......
Page 89: ...APPENDIX A XT IX PCA PowerStation Specifications ...
Page 97: ...Figure A 5 10 1 Physical Dimensions and Panel Cutout Figure A 6 10 1 Rear View ...
Page 99: ...Figure A 9 21 5 Physical Dimensions and Panel Cutout Figure A 10 21 5 Rear View ...