28
Modular Electric HMR Linear Drives
7.7.3 Drive System Installation
NOTE
When installed, both parts of the motor coupling must have a defined
gap dimension “
Y
”. Also note the clearance dimensions in the following
table in relation to the shaft of the motor or gearbox used.
Motor flange
Coupling
housing
Motor coupling
► Insert the
coupling housing
centered into the end cap.
► Mount the
motor coupling
on the drive
shaft with clearance “
X
”
(see table above, depending on type).
► Center the
motor flange
on the
coupling
housing
and tighten the screws.
NOTE
► Adhere to the tightening torques for screws according
to section 7.1 on page 12.
G
øD
øF
E
j6
k6
P
Motor dimensions [mm]
D
min
E
max
F
G
min
G
max.
P
X X
090-270
Y
Z
HMRS08
HMRB08
30
5
6-14
15
20 15
12
-3
1
8
10
20
25 20
13
15
25
30 25
18
HMRS11
HMRB11
35
5
6-16
15
20 15
20
-2
1,5
8
10
20
25 20
13
15
25
30 25
18
HMRS15
HMRB15
50
5
8-24
20
30 20
28
4
2,0
5
15
31
40 30
15
25
41
50 40
25
HMRS18
HMRB18
60
5
10-28
30
40 20
32
4
2,0
10
15
41
50 30
20
25
51
60 40
30
HMRS24
HMRB24
77
4
14-38
40
50 20
35
10
2,5
15
14
51
60 30
25
24
61
70 40
35