24
Modular Electric HMR Linear Drives
7.5.6 Setting up the External Magnetic Switches
Only possible with the IP54 cover!
Retrofitting:
All magnetic switches are mounted via a switch rail to be affixed onto the IP54 cover.
► Remove the
strip
from the IP54 cover.
Setting up the magnetic switches
► Insert the previously aligned magnetic switches into the switch rail (size 1.5 Allen key).
NOTE
Adjust the carriage to the desired position (end position / homing)
and then move the magnetic switch in the T-slot until the switch
point is reached.
Adjusting the switch points (setup)
► Move the magnetic switches until the switch point is reached.
► Tightly clamp the magnetic switch with a size 1.5 Allen key.
Connecting the magnetic switches
► Connect the respective connection cable with the M8 connector for the magnetic switch.
► Secure the loose cable in the T-slot with the cable holders.
► Insert the connection cable in the controller
(refer to section 11.3 for information on ordering connection cables).
End switch E -
Homing switch R
T-slot cable holder
Terminal profile switch groove
HMRB
End switch E +