19
EN
7.4.2 IP54 Cover Assembly
The cover can be retrofitted; refer to section 11.1. on page 45.
The following instructions also apply to retrofitting, converting or maintaining the HMR.
For information on necessary disassembly, refer to section 7.4.1 on page 18.
ATTENTION
It is possible to implement an incorrect assembly sequence.
The cover covers the limit switches on the inside.
► Pay attention to the sequence! Make sure you differentiate between
- HMR installation
- Subsequent assembly of the cover and
- Maintenance of the HMR
Assemble holder cover
► Insert the
cords
to seal the covers in the grooves on the cover.
► Place the
holder cover
on the guide rails 4x
and screw these against the cover.
Mount the strip guides and side covers
► Screw 4x
inner strip guides
onto the carriage and grease lightly.
► Only HMR15, 18, 24: Push the
covers
into the longitudinal grooves on the carrier (clip in) and screw in the
four
fastening screws
.
► Only HMR08, 11: Use
slot nuts
(number corresponding to the stroke length) and screw in the four
fastening
screws
.
NOTE
► Adhere to the tightening torques for screws
according to section 7.1 on page 12.
Cords
Inner strip guide
Cover
HMRB
HMRB
Holder cover
4x fastening screws
Only HMR08, 11: Nuts