7.5.5 Setting up the Internal Magnetic Switches
The IP54 cover must be opened as per section 7.4.1 on page 18.
Tip:
Adjust the carriage to the desired position (end position/homing) and then
move the magnetic switch in the T-slot until the switch point is reached.
► Insert the magnetic switch into the T-slot, if not preassembled
(or loosen it with a size 1.5 Allen key).
► Set up the switch point by moving the magnetic switch until the switch point is reached.
► Tightly clamp the magnetic switch with a size 1.5 Allen key.
Connecting the magnetic switches
ATTENTION
Risk of damage to cable!
Cable shearing and scuffing will cause
failures and damage.
Route cable securely and tightly.
► Cut the magnetic switch cable to the desired length and strip it.
► Route the cable on the PCB according to the terminal assignment, see section 7.5.3 on page 22.
► Secure the loose cable in the T-slot with the cable holders.
► Connect the respective connection cable with the M8 mounted connectors on the cover.
► Insert the connection cable in the controller (refer to section 11.2 on page 46 for information on ordering
connection cables).
End switch E -
Homing switch R
Magnet
Magnet switch
Profile nut with sensor cable
HMRB
End switch E +