6
D_FB-D_1FB 5715-669 UK.indd CM
Prop. Directional Control Valve
Series D*FB / D*1FB
Operation Manual
Parker Hannifin GmbH
Hydraulic Controls Division
Parker D*FB/D*1FB proportional directional control
valves have an integral electronic and requires only
one sole electrical common for the control system.
Different flow sizes, as well as command signal op-
tions are available to achieve an optimal adaption
for different applications.
Characteristics of Valve Driver
The described integral electronic driver combines
all necessary functions for the optimal operation of
the valve. The most important features are:
• digital circuit design
• high dynamic constant current solenoid con-
trol
• differential input stage with various command
signal options
• four quadrant ramp function
• MIN adjustment for deadband compensation
• MAX adjustment to match the command signal
span to the valve operating range
• optional reference o/-10 V for potenti-
ometer supply
• optional four parametrizable preset recall
channels
• standard central connection
• compatible to the relevant European EMC-
standards
• comfortable interface program
Name Plate Example
Block Diagram of Integral Electronics
Code F0/M0 (6+PE)
Code S0/G0 (6+PE)
Code W5 (11+PE)
18
18
S0: 4...12...20mA
G0: 0...±20mA
18
10
10