Prop. Directional Control Valve
Series D*FB / D*1FB
Operation Manual
21
D_FB-D_1FB 5715-669 UK.indd CM
Parker Hannifin GmbH
Hydraulic Controls Division
Parameter overview for basic mode
Parameter
Description
Unit
Parameter Range
Default
Setting
Comment
from
up to
S1
internal Sollwert S1
%
-100
100
0.0
code W5 only
S2
internal Sollwert S2
%
-100
100
0.0
S3
internal Sollwert S3
%
-100
100
0.0
S4
internal Sollwert S4
%
-100
100
0.0
S5
ramp accel. channel A
ms
0
32500
0
S6
ramp decel. channel A
ms
0
32500
0
S7
ramp accel. channel B
ms
0
32500
0
S8
ramp decel. channel B
ms
0
32500
0
P3
MAX channel A
%
50.0
100.0
100.0
P4
MAX channel B
%
50.0
100.0
100.0
P7
MIN channel A
%
0.0
50.0
0.0
P8
MIN channel B
%
0.0
50.0
0.0
P11
polarity command
–
0
1
0
E17
option command
–
1 = ±10V
1 = ±10V
code W5 only
3 = 4-20mA
E19
cable break detection
command
–
0
0 = ±10V
0 = +/-10V
codes S0 & W5
only
1 = 4-20mA
E25
MIN operating threshold
–
0 = 1%
0 = 1%
1 = 0.01%
25
25