background image

Prop. Directional Control Valve

Series D*FB / D*1FB

Operation Manual

7

D_FB-D_1FB 5715-669 UK.indd CM

Parker Hannifin GmbH

Hydraulic Controls Division

Technical Data

General

Model

Proportional directional control valve, direct operated (D*FB), pilot 
operated (D*1FB)

Drive

Proportional solenoid

Mounting Pattern

NG6 (CETOP 3) / NG10 (CETOP 5) 
NG16 (CETOP 7) / NG25 (CETOP 8) / NG32 (CETOP 11)

Installation Position

Any

Hysteresis D1FB*0/D3FB*0

[%] < 

4

  D3FB*3/D*1FB

[%] < 

5

Ambient Temperature Range

[°C] -20...+60

Protection Class

NEMA 4 (IP 65) acc. EN 60529

Vibration Strength

[G] 10 Sinus 5...2000 Hz acc. IEC 68-2-6

30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27

Weight

[kg] NG6: 3 / NG10: 7 / NG16: 11 / NG25: 19.5 / NG32: 61

Hydraulic

Fluid Rate

Hydraulic oil acc. DIN 51524...535, other on request

Viscosity

[SSU] 140...370

Fluid Temperature

[°C] -20...+60

Cleanliness

Purity level class acc. NAS 1638: class 7

Operating Pressure max. (D*FB)
 

Pilot oil intern (D*1FB):

 

Pilot oil extern (D*1FB):

[bar]
[bar]
[bar]

350 for ports P, A, B  /  210 for port T
350 for ports P, A, B, X / 185 for T, Y
350 for ports P, A, B, T, X / 185 for Y

Electrical

Duty Ratio

% 100

Supply Voltage 

Us

VDC 18...30, ripple < 5% eff., surge free

Current Consumption max.

A D1FB: 1.5 / D3FB: 2.0 / D*1FB: 1.5

Pre-Fusing

A D1FB: 2.0 / D3FB: 2.5 / D*1FB: 2.0

Potentiometer supply 

Up

V ± 10 / ± 5 % max. 10 mA

Command Signal Options 

Uc

 

 

 Ic

mA

mA

Codes F0, M0, W5: +10...0...-10, ripple < 0.01 % eff., surge free,  
Ri = 100 kOhm
Codes S0 & W5: 4...12...20, ripple < 0.01 % eff., surge free,  
Ri = 200 Ohm
< 3.6 mA = enable off, > 3.8 mA = enable on (acc. NAMUR NE43)
Code G0: +20...0...-20, ripple < 0.01 % eff., surge free,  
Ri = 200 Ohm

Differential Input Voltage max.

V Codes F0, M0, S0, G0: 30 for terminal D and E against PE (terminal G)

V 11 for terminal D and E against 0V (terminal B)

V Code W5: 30 for terminal 4 and 5 against PE (terminal PE)

V 11 for terminal 4 and 5 against 0V (terminal 2)

Channel Recall Signal 

Uch

V 0...2.5: Off / 5...30: On / Ri = 100 kOhm

Adjustment Ranges 

Min

% 0...50

 Max

% 50...100

 Ramp

s 0...32.5

Interface

RS 232C, parametrizing connection 5pole

EMC

EN 61000-6-2, EN 61000-6-4

Central Connection

Codes F0, M0, S0, G0:  6 + PE acc. EN 175201-804

Code W5: 11 + PE acc. EN 175201-804

Cable Specification

mm² Codes F0, M0, S0, G0: 7 x 1.0 (AWG16) overall braid shield

mm² Code W5: 11 x 1.0 (AWG16) overall braid shield

Cable Length max.

m 50

11

11

Summary of Contents for DFB Series

Page 1: ...n GmbH Hydraulic Controls Division Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 Fax 49 2131 513 230 E mail infohcd parker com Copyright 2010 Parker Hanni n GmbH Operation Manual Series...

Page 2: ...ect or use any product or system it is important that you analyse all aspects of your application and review the informa tion concerning the product or system in the current product catalogue Due to t...

Page 3: ...cope of Supply 10 Mounting 10 Operation Limits 10 Pressure Fluids 10 Electrical Connection 11 Electrical Interfacing 12 5 Operation Instructions 18 ProPxD parameterizing software 18 Screenshot 18 Hard...

Page 4: ...signal Seal NBR different seal compound by request Design series Option D N F B 0 Code Nominal size 1 NG06 CETOP 3 3 NG10 CETOP 5 Code Spool position C E K Code Command signal Function Connection Opti...

Page 5: ...inal size Valve accessories Option Code Valve accessories 0 Standard 8 Monitor switch Code Command signal Function Connec tion Option F0 0 10V 0 10V P B 6 PE Pot supply M0 0 10V 0 10V P A 6 PE Pot sup...

Page 6: ...functions for the optimal operation of the valve The most important features are digital circuit design high dynamic constant current solenoid con trol differential input stage with various command s...

Page 7: ...5 for T Y 350 for ports P A B T X 185 for Y Electrical Duty Ratio 100 Supply Voltage Us VDC 18 30 ripple 5 eff surge free Current Consumption max A D1FB 1 5 D3FB 2 0 D 1FB 1 5 Pre Fusing A D1FB 2 0 D3...

Page 8: ...8 D_FB D_1FB 5715 669 UK indd CM Prop Directional Control Valve Series D FB D 1FB Operation Manual Parker Hanni n GmbH Hydraulic Controls Division Signal ow diagram 12 12...

Page 9: ...tended Themanufacturerisnotliableforwarranty claims resulting from this Common Instructions We reserve the right for technical modi cations of the described product Illustrations and drawings within t...

Page 10: ...K360 D111FB BK386 Tighten the bolts crisscross with the following torque values D1FB 7 6 Nm D3FB 13 2 Nm D31FB 13 2 Nm D41FB 13 63 Nm D91FB 108 Nm D111FB 517 Nm Insuf cient condition of the valve moun...

Page 11: ...ion 8 12 mm Cable length max 50 m For cable lengths 50 m consult factory The connection cable is coupled to the female connector by solder joints Skinning lengths for the connecting cable Theconnectio...

Page 12: ...uction may create irreparable damage of valve resp incorporated system parts The shielding has to be assembled according the outline below The backshell nut of the cable gland has to be tighten with a...

Page 13: ...hen the command falls below 3 6 mA This determination follows the NAMUR speci ca tion NE43 NAMUR is an association of users of process control technology Command signal input Thecommandsignalfortheval...

Page 14: ...ode F0 M0 6 PE Wiring diagram of voltage command input 10 0 10 V via potentiometer Code F0 M0 6 PE The external potentiometer is fed via the output potentiometer supply Topreventthisoutputfrom overloa...

Page 15: ...W5 11 PE Uc 0V command signal control system valve command signal 0 10 V I 4 5 0 V I 4 5 0 10 V I 4 5 4 5 function D FB D 1FB function valve command signal 0 10 V U 4 5 0 V U 4 5 0 10 V U 4 5 potenti...

Page 16: ...diagram of current command input 4 12 20 mA Code W5 11 PE B C D E F A Ic Ic 12 20 mA I D E 12 mA I D E 4 12 mA I D E 3 6 mA I D E 3 8 mA I D E command signal valve command signal control system actuat...

Page 17: ...ll be assessed as input signal Thepresetchannelshavepriorityagainsttheanalog signal input for the external command Atadditivechannelrecalltheinternalsignalpresets of the recall channels as well as a p...

Page 18: ...ise distortion of the display may occur ProPxD parameterizing software The ProPxD software permits comfortable param etersettingforthemoduleelectronic Viatheclearly arrangedentrymasktheparameterscanbe...

Page 19: ...nation drive resp installation path if needed i e if the storage space on drive c is not suf cient Pleaseansweralso ok ifattheendoftheinstallation the program reports any system information After succ...

Page 20: ...orrect settings mayleadtomalfunction Incaseofparameter changes shut the drive down To prevent an unauthorized access for the expert mode a pass word is requested The name is parker and cannot be chang...

Page 21: ...internal Sollwert S3 100 100 0 0 S4 internal Sollwert S4 100 100 0 0 S5 ramp accel channel A ms 0 32500 0 S6 ramp decel channel A ms 0 32500 0 S7 ramp accel channel B ms 0 32500 0 S8 ramp decel channe...

Page 22: ...noise S8 ramp decel channel B Adjustment of ramp rate for decreasing of the negative signal polarity To avoid switching noise P3 MAX Adjustment of maximum signal span for positive output signal To mat...

Page 23: ...signal channel S1 To avoid switching noise S12 ramp for internal command signal 2 Adjustment of the ramp rate for the internal command signal channel S2 To avoid switching noise S13 ramp for internal...

Page 24: ...eters During parameter loading from the electronics memory the preset parameters from the left hand screen display may be rejected or maintained The chosen module valve isn t the same as the con necte...

Page 25: ...on arising during operation friction wear impurities from the environment Basically a purity level class of 7 acc NAS 1638 is required Pay attention to maintenance details Flushing Itisrecommendedto u...

Page 26: ...only speed variations at unchanging command different speeds depending on travel direction speed too low drifting without command possible reasons for malfunction corrective actions x hydraulic pump r...

Page 27: ...0 S0 G0 female connector 6 PE ordering code 5004072 Code W5 female connector 11 PE ordering code 5004711 D41FB bolt kit ordering code BK320 Code F0 M0 S0 G0 female connector 6 PE ordering code 5004072...

Page 28: ...1 99 44 99 92 12 Our homepage www parker com provides further electronic documentation to several product areas Hotline in Europe Phone 00800 2727 5374 For further questions please contact us Parker H...

Reviews: