D_FB-D_1FB 5715-669 UK.indd CM
Prop. Directional Control Valve
Series D*FB / D*1FB
Operation Manual
Parker Hannifin GmbH
Hydraulic Controls Division
Cable Specification
The connection of the valve electronic to a PC
requires a special cable. It may be ordered under
code 40982923. The cable has to be inserted
between an unused serial port COM1 or COM2 of
the PC and the 5pole socket connector of the valve
electronic (parametrizing connector).
Before connecting of the parametrizing cable
a cover plug has to be removed from the
electronic housing.
Attention! The valve electronic provides no
USB interface, but can only be parametrized
via an RS-232 - connection. Therefore the
usage of USB standard cables is permitted
and may result in damaging of valve resp. PC.
Hardware requirements
• PC with operating system from Windows® 95
upwards
• Interface
RS-232
• display resolution min. 800 x 600
• connection cable between PC and electronic
module
• storage requirement approx. 4 MB
It is recommended to select “small fonts” at
the display setting, otherwise distortion of the
display may occur.
ProPxD parameterizing software:
The ProPxD software permits comfortable param-
eter setting for the module electronic. Via the clearly
arranged entry mask the parameters can be noticed
and modified. Storage of complete parameter sets
to floppy or hard disk is possible as well as printout
or record as a text file for further documentation.
Stored parameter sets may be loaded anytime and
transmitted to other valves. Inside the electronic a
nonvolatile memory stores the data with the option
for recalling or modification.
Features
• comfortable editing of all parameters
• depiction and documentation of parameter sets
• storage and loading of optimized parameter
adjustments
• executable with all actual Windows
®
operating
systems from Windows
®
95 upwards
•
plain communication between PC and electronic
via serial interface RS-232.
Comfortable interface, see Parker freeware available
from [email protected].
5. Operating Instructions
Basically the valve performs the task of converting a
command signal into a proportional spool stroke with
the highest possible dynamic. For these purposes
the input value will be electronically processed and
provides via a power amplifier stage the required
current for the valve solenoid.
ProPXD screenshot