background image

18

D_FB-D_1FB 5715-669 UK.indd CM

Prop. Directional Control Valve

Series D*FB / D*1FB

Operation Manual

Parker Hannifin GmbH

Hydraulic Controls Division

Cable Specification

The connection of the valve electronic to a PC 
requires a special cable. It may be ordered under 
code 40982923. The cable has to be inserted 
between an unused serial port COM1 or COM2 of 
the PC and the 5pole socket connector of the valve 
electronic (parametrizing connector). 

 

 

 

 

 

 

 

 

Before connecting of the parametrizing cable 
a cover plug has to be removed from the 
electronic housing.

 

Attention! The valve electronic provides no 
USB interface, but can only be parametrized 
via an RS-232 - connection. Therefore the 
usage of USB standard cables is permitted 
and may result in damaging of valve resp. PC.

Hardware requirements 

•  PC with operating system from Windows® 95 

upwards 

• Interface 

RS-232 

 

•  display resolution min. 800 x 600 

•  connection cable between PC and electronic 

module 

•  storage requirement approx. 4 MB 

 

It is recommended to select “small fonts” at 
the display setting, otherwise distortion of the 
display may occur.

ProPxD parameterizing software:

The ProPxD software permits comfortable param-
eter setting for the module electronic. Via the clearly 
arranged entry mask the parameters can be noticed 
and modified. Storage of complete parameter sets 
to floppy or hard disk is possible as well as printout 
or record as a text file for further documentation. 
Stored parameter sets may be loaded anytime and 
transmitted to other valves. Inside the electronic a 
nonvolatile memory stores the data with the option 
for recalling or modification.

Features

•  comfortable editing of all parameters

•  depiction and documentation of parameter sets

•  storage and loading of optimized parameter 

adjustments

•  executable with all actual Windows

®

 operating 

systems from Windows

®

 95 upwards

• 

plain communication between PC and electronic 
via serial interface RS-232.

Comfortable interface, see Parker freeware available 
from [email protected].

5. Operating Instructions

Basically the valve performs the task of converting a 
command signal into a proportional spool stroke with 
the highest possible dynamic. For these purposes 
the input value will be electronically processed and 
provides via a power amplifier stage the required 
current for the valve solenoid.

ProPXD screenshot

22

22

Summary of Contents for DFB Series

Page 1: ...n GmbH Hydraulic Controls Division Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 Fax 49 2131 513 230 E mail infohcd parker com Copyright 2010 Parker Hanni n GmbH Operation Manual Series...

Page 2: ...ect or use any product or system it is important that you analyse all aspects of your application and review the informa tion concerning the product or system in the current product catalogue Due to t...

Page 3: ...cope of Supply 10 Mounting 10 Operation Limits 10 Pressure Fluids 10 Electrical Connection 11 Electrical Interfacing 12 5 Operation Instructions 18 ProPxD parameterizing software 18 Screenshot 18 Hard...

Page 4: ...signal Seal NBR different seal compound by request Design series Option D N F B 0 Code Nominal size 1 NG06 CETOP 3 3 NG10 CETOP 5 Code Spool position C E K Code Command signal Function Connection Opti...

Page 5: ...inal size Valve accessories Option Code Valve accessories 0 Standard 8 Monitor switch Code Command signal Function Connec tion Option F0 0 10V 0 10V P B 6 PE Pot supply M0 0 10V 0 10V P A 6 PE Pot sup...

Page 6: ...functions for the optimal operation of the valve The most important features are digital circuit design high dynamic constant current solenoid con trol differential input stage with various command s...

Page 7: ...5 for T Y 350 for ports P A B T X 185 for Y Electrical Duty Ratio 100 Supply Voltage Us VDC 18 30 ripple 5 eff surge free Current Consumption max A D1FB 1 5 D3FB 2 0 D 1FB 1 5 Pre Fusing A D1FB 2 0 D3...

Page 8: ...8 D_FB D_1FB 5715 669 UK indd CM Prop Directional Control Valve Series D FB D 1FB Operation Manual Parker Hanni n GmbH Hydraulic Controls Division Signal ow diagram 12 12...

Page 9: ...tended Themanufacturerisnotliableforwarranty claims resulting from this Common Instructions We reserve the right for technical modi cations of the described product Illustrations and drawings within t...

Page 10: ...K360 D111FB BK386 Tighten the bolts crisscross with the following torque values D1FB 7 6 Nm D3FB 13 2 Nm D31FB 13 2 Nm D41FB 13 63 Nm D91FB 108 Nm D111FB 517 Nm Insuf cient condition of the valve moun...

Page 11: ...ion 8 12 mm Cable length max 50 m For cable lengths 50 m consult factory The connection cable is coupled to the female connector by solder joints Skinning lengths for the connecting cable Theconnectio...

Page 12: ...uction may create irreparable damage of valve resp incorporated system parts The shielding has to be assembled according the outline below The backshell nut of the cable gland has to be tighten with a...

Page 13: ...hen the command falls below 3 6 mA This determination follows the NAMUR speci ca tion NE43 NAMUR is an association of users of process control technology Command signal input Thecommandsignalfortheval...

Page 14: ...ode F0 M0 6 PE Wiring diagram of voltage command input 10 0 10 V via potentiometer Code F0 M0 6 PE The external potentiometer is fed via the output potentiometer supply Topreventthisoutputfrom overloa...

Page 15: ...W5 11 PE Uc 0V command signal control system valve command signal 0 10 V I 4 5 0 V I 4 5 0 10 V I 4 5 4 5 function D FB D 1FB function valve command signal 0 10 V U 4 5 0 V U 4 5 0 10 V U 4 5 potenti...

Page 16: ...diagram of current command input 4 12 20 mA Code W5 11 PE B C D E F A Ic Ic 12 20 mA I D E 12 mA I D E 4 12 mA I D E 3 6 mA I D E 3 8 mA I D E command signal valve command signal control system actuat...

Page 17: ...ll be assessed as input signal Thepresetchannelshavepriorityagainsttheanalog signal input for the external command Atadditivechannelrecalltheinternalsignalpresets of the recall channels as well as a p...

Page 18: ...ise distortion of the display may occur ProPxD parameterizing software The ProPxD software permits comfortable param etersettingforthemoduleelectronic Viatheclearly arrangedentrymasktheparameterscanbe...

Page 19: ...nation drive resp installation path if needed i e if the storage space on drive c is not suf cient Pleaseansweralso ok ifattheendoftheinstallation the program reports any system information After succ...

Page 20: ...orrect settings mayleadtomalfunction Incaseofparameter changes shut the drive down To prevent an unauthorized access for the expert mode a pass word is requested The name is parker and cannot be chang...

Page 21: ...internal Sollwert S3 100 100 0 0 S4 internal Sollwert S4 100 100 0 0 S5 ramp accel channel A ms 0 32500 0 S6 ramp decel channel A ms 0 32500 0 S7 ramp accel channel B ms 0 32500 0 S8 ramp decel channe...

Page 22: ...noise S8 ramp decel channel B Adjustment of ramp rate for decreasing of the negative signal polarity To avoid switching noise P3 MAX Adjustment of maximum signal span for positive output signal To mat...

Page 23: ...signal channel S1 To avoid switching noise S12 ramp for internal command signal 2 Adjustment of the ramp rate for the internal command signal channel S2 To avoid switching noise S13 ramp for internal...

Page 24: ...eters During parameter loading from the electronics memory the preset parameters from the left hand screen display may be rejected or maintained The chosen module valve isn t the same as the con necte...

Page 25: ...on arising during operation friction wear impurities from the environment Basically a purity level class of 7 acc NAS 1638 is required Pay attention to maintenance details Flushing Itisrecommendedto u...

Page 26: ...only speed variations at unchanging command different speeds depending on travel direction speed too low drifting without command possible reasons for malfunction corrective actions x hydraulic pump r...

Page 27: ...0 S0 G0 female connector 6 PE ordering code 5004072 Code W5 female connector 11 PE ordering code 5004711 D41FB bolt kit ordering code BK320 Code F0 M0 S0 G0 female connector 6 PE ordering code 5004072...

Page 28: ...1 99 44 99 92 12 Our homepage www parker com provides further electronic documentation to several product areas Hotline in Europe Phone 00800 2727 5374 For further questions please contact us Parker H...