Prop. Directional Control Valve
Series D*FB / D*1FB
Operation Manual
11
D_FB-D_1FB 5715-669 UK.indd CM
Parker Hannifin GmbH
Hydraulic Controls Division
Electrical Connection
The electrical connection of the valve takes place
by one common cable, which is coupled to the
integrated electronic driver by a central connector
assembly.
The connection Codes F0/S0 requires a 6 + PE
female connector EN 175201-804.
The female connector has to be ordered
separately under article nr. 5004072.
A female connector with metal housing is
required! Plastic made models may create
function problems due to insufficient EMC-
characteristics.
The connecting cable has to comply to the follow-
ing specification:
Cable type
control cable, flexible,
7 conductors, overall braid
shield
Cross section
min. AWG16/1.0 mm
2
Outer dimension
8...12 mm
Cable length
max. 50 m
For cable lengths > 50 m consult factory.
The connection cable is coupled to the female
connector by solder joints.
Skinning lengths for the connecting cable:
The connection Code W5 requires a 11 + PE female
connector EN 175201-804.
The female connector has to be ordered
separately under article nr. 5004711.
A female connector with metal housing is
required! Plastic made models may create
function problems due to insufficient EMC-
characteristics.
The connecting cable has to comply to the follow-
ing specification:
Cable type
control cable, flexible,
11 conductors, overall braid
shield
Cross section
min. AWG16/1.0 mm
2
Outer dimension
12...15 mm
Cable length
max. 50 m
For cable lengths > 50 m consult factory.
The connection cable is coupled to the female
connector by crimp contacts.
Skinning lengths for the connecting cable:
For the workmanlike termination of the crimp
contacts the tool # 932 507-001 – supplier:
Hirschmann – is required.
Do not disconnect cable socket under tensi-
on!
15
15