2
Connection Assignments and Functions
Connection Assignments and Functions
Connection Assignments and Functions
Connection Assignments and Functions
07-02-12-02-EN-V1215.doc / Type:
638
37
2.10
Fieldbus Interface COM2 in Combination with COM3
(OPTION SLOT A/B)
●
Pinning for Interbus S (RP IBS)
Remote OUT -
Outgoing Interface (SUB D09 Socket)
Module: RP IBS
PIN Function
Designation
1
Data Line OUT Forward
(error voltage A)
DO2
2
Data Line IN Backward
(error voltage A)
DI2
3
Reference Potential
IBS-GND
4
-
-
5
VCCI
+5V
6
Data Line OUT Forward
(error voltage B)
/DO2
7
Data Line IN Backward
(error voltage B)
/DI2
8
-
-
9
Reporting Input *
RBST
* for additional Interbus S - Interfaces
Remote IN -
Incoming Interface (SUB D09 Plug)
Module: RP IBS
PIN Function
Designation
1
Data Line IN Forward
(error voltage A)
DO1
2
Data Line OUT Backward
(error voltage A)
DI1
3
Reference Potential
IBS-GND
4
-
-
5
-
-
6
Data Line IN Forward
(error voltage B)
/DO1
7
Data Line OUT Backward
(error voltage B)
/DI1
8
-
-
9
-
-
with galvanic isolation