12
Technical Data
Technical Data
Technical Data
Technical Data
112
07-02-12-02-EN-V1215.doc / Type:
638
●
Analog - outputs
measuring pin X10.17
signal range
-10V.....0.....+10V
magnifier function can be normed
resolution
10 bit, independend of norming
internal resistance
1,64 kOhm
●
measuring pin X10.6
signal range
-10V.....0.....+10V
magnifier function can be normed
resolution
8 bit, independend of norming
internal resistance
1,64 kOhm
●
Thermo-Control X30
No galvanic Separation to the Control Circuit
Measurement Voltage at 100 / 1640 / 9999 Ohm 0,15V / 1,7V / 3,8V
Measurement Range
100..9999Ohm, short-circuit proof
(Thermo switch evaluable)
●
Thermo-Control X62
Galvanic Separation to the Control Circuit
Galvanic Separation to the Power Circuit
Basic Isolated in acc. with EN 61800-5-1
Double Isolation in acc. with EN 61800-5-1
Measurement Voltage at 100 / 1640 / 6000 Ohm
0,15V / 1,7V / 3,2V
Measurement Range
100..6000Ohm, short-circuit proof
(Thermo switch evaluable)
●
Brake-Control X62
Galvanic Separation to the Control Circuit / -
Power Circuit
Basic Isolation in acc.
with EN 61800-5-1
Nominal Voltage Supply
24V DC
Max. Brake Current
2A (for UL conditions Imax. = 1.2A)
Contact Protection for inductive Load
Internal Varistor (BR+ <-> BR-)