![Parker 638 series Product Manual Download Page 88](http://html1.mh-extra.com/html/parker/638-series/638-series_product-manual_3729142088.webp)
9
Safe
Safe
Safe
Safe Torque
Torque
Torque
Torque Off (STO)
Off (STO)
Off (STO)
Off (STO)
88
07-02-12-02-EN-V1215.doc / Type:
638
9.3
Configuration and Parameter Settings
●
General Instructions for Parameter Settings
The safe torque off, ’
STO’,
basic function is a built-in, hardware oriented safety function which is
not
configurable
.
Depending upon the specific application however, it is possible to alter specific settings on the drive side
which can increase the operational safety factor.
The configuration and programming of the safety parameters can be accomplished utilizing the Diagnosis
and Parameter Setting screen in EASYRIDER for Windows.
This configuration process has been designed to assist the user in making the proper parameter settings,
in an attempt to eliminate the potential for systematic programming errors and/or improper parameter
settings.
Required Actions for the Configuration of Relevant Safety Parameters
•
Special password protected access is required to reach the relevant
safety parameter setting screens.
•
The transmission of the data through the PC interface follows a specially
designed protected procedure, including: CRC check, drive specific
password and a double confirmation and acknowledgement process for
the parameter values entered.
•
After the confirmation and acknowledgement of the entered data, the
parameter values are saved in the drive and protected even in the event
of a power loss.
•
The parameter values are stored twice within the drive, and provide for
automatic periodic verification of the memory cell accordance.
•
Any other means of accessing the safety and security related data, as
described here, is not permitted.
•
The creation of a parameter protocol, which can be stored as a
document with appropriate name and date information.
The relevant safety, secondary function parameters – Acknowledgement and Active
Time Delay, can only be set within the Configuration Safety dialog box. The data are
saved under Parameter Data utilizing the suffix *.WDD. But the safety relevant data
will not transmit by “Transmit Parameters”.
In the Configuration Safety dialog box the relevant safety parameters will shown by
an open parameter file. The user has to transmit the parameter safely to the drive.
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]