Safety I/O Specifications
OM1305066E26
35
6.1.8 Emergency stop output
An output terminal to output the emergency stop state.
(No-voltage relay contact output, Contact ratings: 5 A, 30
VDC, minimum load 100 mA 5 VDC)
Open the terminals in
an emergency state.
There are four kinds of emergency stop outputs as follows
.
1 Emergency stop output
How connectors
“OUTMD0” to “OUTMD6”
of the Safety card are
shorted determines its
output conditions.
2
Reserved emergency
stop output
3
Emergency stop output
for application
How connectors
“OUTMD0” to “OUTMD6”
of the Safety card are
shorted does NOT
change its output
conditions.
4
Reserved emergency
stop output for application
Emergency stop output
for application
Reserved emergency stop
Emergency stop output
Reserved emergency stop
output for application
output