Connection
OM1305066E26
24
5.4.2 Wiring primary cables (For T*/Y* specification)
* the input power cable is customer preparation.
(1) Remove the cover of the terminal box. (four M4
screws) Pass input power cables through the cord
lock and then connect it to the input terminals.
(2) Put the cover of the terminal box back in place.
(3) Protect the cable coating with the attached rubber
sheet and then set the saddle over the rubber sheet to
fix the cable to the lower part of the controller.
Outside diameter of cord lock
adaptive cable
32 mm-34 mm
Note
Connecting screw “A”
• Do not use a wrench
• Tightening torque:
2.5 N•m to 3.0 N•m
Recommended terminal
at “
A
”.
(14 mm
2
M6)
27.5
11.5
10
6.4
12
5.8
9
Terminal box
M5 screw holes
for saddle fixing
Terminal box
cover
(A)
CAUTION
Do not connect a primary power cable of peripheral equipment to the breaker or terminal block
inside the controller, or it will cause malfunction or breakdown.