![background image](http://html.mh-extra.com/html/panasonic/wv-x6511n/wv-x6511n_operating-instructions-manual_1511972133.webp)
–
when there are reflections from light entering the front glass due to reflections from a window or
road, or from a backlight
–
when the target is hidden behind a utility pole or other objects
–
when the subject passes by other moving objects
–
when the target moves too fast or too slow
–
when the camera is shaking
•
In no event shall we be liable to any consequential inconvenience, or loss or damage, arising out of
the settings or results of the auto tracking system.
•
We recommend that you use this setting under the following setting conditions to improve the detection
accuracy.
–
set the size of the tracking target to over 1/5 of the monitoring screen (lengthwise)
set the tilt angle within 20° - 55° (
Procedure to setup auto track cooperation
If 2 or more cameras that support the auto track function are used, tracking of targets can be coordinated
between cameras. (Auto track cooperation setting)
For example, the procedure for getting Camera 2 (IP address: 192.168.0.12) to take over auto tracking from
Camera 1 (192.168.0.11) when the tracking target enters into alarm area No.1 during auto tracking as shown
below, is explained here.
Camera 1
IP address: 192.168.0.11
Camera 2
IP address: 192.168.0.12
Panasonic alarm protocol notification is sent
During auto tracking,
Camera 1 checks for targets
in alarm area No. 1
Camera 2 moves to
the set preset position
and starts auto tracking
Alarm area No. 1
[2]
[3]
[1]
1.
Set an alarm area to Camera 1 in the area where you want to perform auto track cooperation.
Display the “Auto track setting” page.
With “Auto track alarm” select “On(In preset alarm area)” and click the [Set] button.
Select “1” from the “Area No.” pull-down menu of “Area select” in “Alarm area”.
While monitoring images, perform the pan/tilt/zoom, and then set the alarm area.
Click the [Set] button.
2.
On Camera 2, configure the preset position for received notification commands. (Configure the preset
position so that alarm area No. 1 enters the screen as configured in step 1.)
Display the “Preset position” setting page. (
Select a preset number that you want set from the “Preset” pull-down menu.
While monitoring images, perform the pan/tilt/zoom, and then set the preset position.
Click the [Set] button.
3.
Set Camera 1 (IP address: 192.168.0.11) to notify commands.
Display the “Notification” screen from the “Alarm” page. (
®
From “Panasonic alarm protocol”, set “Panasonic alarm protocol” to “On” and click the [Set] button.
Operating Instructions
133
2 Settings