2.3.2.2 Alarm: Configure the terminal and VMD (alarm setup menu)
The settings relating to actions when an alarm is detected can be configured in this section.
Alarm
[Terminal 1]
Determine how to use terminal 1.
•
Off:
Not used.
•
Alarm input(TRM1):
Receives terminal alarm input.
–
Close:
An alarm is detected when the terminal status is changed to “On”.
–
Open:
An alarm is detected when the terminal status is changed to “Off”.
•
Black & white input:
Receives the black & white input. (When the input is set to “On”, the black & white
mode is activated)
•
Auto time adjustment:
Receives time setting through terminal input. When the signal is entered, if the
time difference from the hour (every hour) is less than 29 minutes, the time is adjusted to 00 minutes 00
seconds. The time is not changed in operations which reset the time under 5 seconds. If you select auto
time adjustment, the pull-down menu to select close or open is displayed.
–
Close:
Performs auto time adjustment when the terminal status is changed to “Close”.
–
Open:
Performs auto time adjustment when the terminal status is changed to “Open”.
•
Default:
Off
[Terminal 2]
Determine how to use terminal 2.
•
Off:
Not used.
•
Alarm input(TRM2):
Receives terminal alarm input.
–
Close:
An alarm is detected when the terminal status is changed to “On”.
–
Open:
An alarm is detected when the terminal status is changed to “Off”.
•
Alarm output:
Alarm output will be carried out according to the settings for “Output terminal” (