Default:
Off
[Terminal 3]
Determine how to use terminal 3.
•
Off:
Not used.
•
Alarm input(TRM3):
Receives terminal alarm input.
–
Close:
An alarm is detected when the terminal status is changed to “On”.
–
Open:
An alarm is detected when the terminal status is changed to “Off”.
•
AUX output:
AUX output is carried out. The [AUX] button will be displayed on the “Live” page.
•
Default:
Off
[VMD alarm]
Select an auto track alarm to be used from the following.
•
On:
If the VMD area is not configured, the entire region is configured. To configure the VMD area, use the
[VMD area] tab on the “Alarm” page. (
®
•
Off:
Disables all VMD states.
•
Default:
Off
[Auto track alarm]
Select an auto track alarm to be used from the following.
•
Off:
Not used.
•
On(Immediate):
Alarms are continuously outputted during auto tracking. (Outputs are made at 5 second
intervals.)
•
On(After alarm wait time):
Alarms are outputted only once when the auto tracking is continuously
performed for a set period.
•
On(In preset alarm area):
While tacking, if the tracking target enters the set alarm area, an alarm is
outputted once.
•
Default:
Off
Note
•
When “On(After alarm wait time)” is selected, it is required to set “Alarm wait time” in the auto track
setting. (
[Audio detection alarm]
•
On:
If audio detection is not configured, set audio detection to “On”. To set the sensitivity of audio detection,
set using the [Audio detection] tab on the “Alarm” page. (
®
•
Off:
Disables audio detection.
•
Default:
Off
[Alarm deactivation time]
Set the duration for which detection is not to be performed after an alarm has been detected. For example, by
using this function you can prevent mail from being sent too often when the E-mail notifications are configured
to be sent to cellular phones when an alarm is detected.
5 – 600 seconds
•
Default:
5s
Note
•
The duration of the alarm deactivation time can be specified for each type of alarm. For example,
during the time when detections for “Terminal alarm 1” are not made, detections for “VMD alarm”
can be made.