289
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
7.3.2.
Toner Density Control (TDC) Adjustment
1. Press the "FUNCTION", "ORIGINAL SIZE (LEDGER/A3)" and "3" keys simultaneously in that order to
enter the Service Mode.
2. Press the "8" key to enter the F8 Mode.
3. Press the "START" key.
4. Press the "0”, "9" and "START" keys sequentially to enter the F8 Mode code "09".
5. Press the "START" key to begin the Automatic TDC sensor gain adjustment.
Note:
Do not touch any keys or turn the Power Switch Off until the adjustment cycle stops
(approximately 7 minutes).
Then, wait for approximately 30 sec. again for QUANTUM to start automatically.
Do not touch any keys or turn the Power Switch Off until the QUANTUM adjustment cycle stops
(approximately 1-2 minutes). Refer to the Sequence Chart below.
7.3.3.
Black Density Sensor Output Gain Adjustment
1. Press the "1", "4" and "START" keys sequentially to enter the F8 Mode code "14".
2. Press the "START" key for Automatic Black density sensor output gain adjustment.
Note:
Do not touch any keys or turn the Power Switch Off until the adjustment cycle stops.
Refer to the Sequence Chart below.
3. Press the "STOP" key.
4. Press the "6" key to enter the F6 Mode.
5. Write the contents of F6-21, 26 and 65 on the memory sheet (included inside the 2nd Paper Tray).
6. Press the "STOP" key.
7. Press the "FUNCTION" and "C" (CLEAR) keys simultaneously to exit the Service Mode.
7.3.4.
Set the Date and Time
1. Press the "FUNCTION" key.
2. Touch the button.
(DP-3510/3520/4510/4520/6010/6020) : "GENERAL FUNCTIONS" button
(DP-3530/4530/6030)
: "GENERAL SETTINGS" button
3. Select the "04 Key Operator Mode".
4. "Input Identification Code" (default is 0000).
5. Touch the "OK" button.
6. Touch the
button to advance to:
(DP-3510/3520/4510/4520/6010/6020) : 05/08 Display Screen of General Settings
(DP-3530/4530/6030)
: 05/09 Display Screen of General Settings
7. Select the "20 Date Time Setting".
8. Touch the "CHANGE" button to input the new Date and Time. (MM/dd/yyyy hh:mm) [24-hour format].
9. After setting the new information, touch "OK" button on the Display Panel.
10. Press the "RESET" key, to exit the General Functions mode.
TDC Adjust
Gain Adjust
F8-09 (Installation & Developer Replace)
Wait
QUANTUM
QUANTUM
F8-14 (Installation & OPC Replace)
7 min
30 sec
30 sec
30 sec-1 min
Wait
1-2 min
1-2 min
Automatically
Automatically
Summary of Contents for Workio DP-3510
Page 4: ...4 Beispiel DP 6530 4530 6030 Hinweis...
Page 424: ...424 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Page 425: ...425 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Page 474: ...474 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 memo...
Page 842: ...memo...
Page 858: ...DZZSM00298...