135
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
3.6.3.
Updating the Firmware using a PC via the Parallel Port
1. Before starting, print the F5 & F6 Parameters (Copier) Lists.
2. Turn the Main Power Switch on the back of the unit (not the side of the unit) to the OFF (O) position.
3. Connect the machine to the PC with a Parallel Printer Cable.
4. Turn the Main Power Switch on the back of the unit to the ON (I) position.
5. Install the Panasonic Firmware Programming Wizard software to the PC.
(Refer to the Firmware Update Tool Operating Instructions)
6. Perform the Copy Service Mode F9-07-01 (Update from parallel port).
Now the machine is ready to accept programming firmware code from the PC.
7. Start the Panasonic Firmware Program using the Wizard.
8. The firmware is copied into the machine.
9. After the update is completed, the machine reboots itself and returns to standby.
10. Perform the Copy Service Mode F9-06-00 (Parameter initialize).
11. Turn the Main Power Switch on the back of the unit (not the side of the unit) to the OFF (O) position.
12. Disconnect the Parallel Printer Cable from the machine.
13. Turn the Main Power Switch on the back of the unit to the ON (I) position.
14. Reprogram the F5 & F6 Parameters (Copier) according to the lists printed in Step 1 above if the
settings are other than factory default.
3.6.4.
Updating the Firmware using the Master Firmware Card
1. Before starting, print the F5 & F6 Parameters (Copier) Lists.
2. Turn the Main Power Switch on the back of the unit (not the side of the unit) to the OFF (O) position.
3. Install the appropriate Master Firmware Card into the machine.
4. Turn the Main Power Switch on the back of the unit to the ON (I) position.
5. Press the "FUNCTION", "ORIGINAL SIZE (LEDGER/A3)" and "3" keys simultaneously in that order
to enter the Service Mode.
6. Perform the Copy Service Mode F9-07-00 (Update from master card).
7. The firmware is copied into the machine.
8. After the update is completed, the machine reboots itself and returns to standby.
9. Perform the Copy Service Mode F9-06-00 (Parameter initialize).
10. Turn the Main Power Switch on the back of the unit (not the side of the unit) to the OFF (O) position.
11. Remove the Master Firmware Card from the machine.
12. Turn the Main Power Switch on the back of the unit to the ON (I) position.
13. Reprogram the F5 & F6 Parameters (Copier) according to the lists printed in Step 1 above if the
settings are other than factory default.
Note:
After the update is completed, the machine reboots itself and returns to standby mode.
Repeat the above steps if there are additional firmware code files to be updated.
Confirm that the update was successfully completed by checking the Firmware Version with F9
Parameters F9-02-xx.
Caution:
If the unit does not boot up properly in step 8, refer to 3.6.8. (Firmware Emergency Recovery)
Summary of Contents for Workio DP-3510
Page 4: ...4 Beispiel DP 6530 4530 6030 Hinweis...
Page 424: ...424 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Page 425: ...425 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Page 474: ...474 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 memo...
Page 842: ...memo...
Page 858: ...DZZSM00298...