37
Settings relating to the terminal alarm [Terminal Setup]
Set event actions at a terminal alarm occurrence.
Screenshot 1
Click the [Event] button in the "Setup" panel then click
the "Terminal Setup" tab. The "Terminal Setup" page
will be displayed.
Note:
Action to be taken at a command alarm occurrence
will be affected by this setting.
Step 1
Perform the settings for the following items for each ter-
minal alarm channel.
[REC CAM]
Performs the settings for a camera channel used for
recording.
[PRESET]
Enter the preset position (1 - 256) to which the camera
will move at a terminal alarm occurrence for each termi-
nal.
When no position is selected (blank), the camera does
not move to any preset position.
[Output Terminal]
Select the output terminal (--, TRM1 - TRM16) that out-
puts alarm signals at a terminal alarm occurrence.
When "--" is selected, alarm signals will not be output.
Step 2
Click the [SET] button after completing the settings.