Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
70
<Using NPN output>
Emitter
Emitter
Receiver
Receiver
K1
K2
+ 24V DC
+20
-30
%
−
Gray cable
Gray cable
(with black line)
(Brown) +V
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
*S1
Interlock function
Valid (manual reset)
External device monitor function Invalid
Auxiliary output
Not possible
*Symbols
Switch S1
0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission
K1, K2: Safety relay unit, etc.
Note: For information on reset, refer to
Summary of Contents for SF4D-*-01 Series