Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
57
*S1
Switch S1
●
Test / Reset input
Manual reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note), Open: Emission
Auto reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt
● Interlock setting input, Override input, Muting input A / B, External device monitor input
Vs to Vs − 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid
Note: Vs is the supply voltage.
<Reference>
K1, K2: External device (forcible guide relay or magnetic con
ta
ctor)