4.3.3.
Information Codes: 404, 405, 407
START
END
Is communication with
reference unit successful?
Change Function Parameter
#010: Reduce Tx Attenuation
Level
Yes
No
Yes
No
Change Function Parameter
#017: Reduce Tx Modem
Speed
Does the problem still occur?
Replace the SC PCB.
Does the problem still occur?
Change Function Parameter
#025: Communication
Startup to 2nd
Does the problem still occur?
END
Does the problem still occur?
Check the telephone line
condition.
Does the problem still occur?
Check the remote unit.
(Recording paper may have
run out or paper may have
jammed.)
Refer to Sect. 4.6.
Yes
No
Yes
No
Yes
No
Yes
No