120
Function Parameter Table
No.
Parameter
Selections
Function
000 MON/TEL DIAL
1 = Monitor
2 = TEL/DIAL
Selects whether the machine starts to TX
automatically during On-Hook dialing.
Monitor
: Start to TX after pressing START
TEL/DIAL : Start to TX automatically
001 ALARM STATUS 1 = OFF
2 = Timer (6 sec.)
3 = Constant
Selects the No Paper or No Toner alarm status.
OFF
: Alarm is disabled.
Timer
: Alarm will shut off after 6 seconds.
Constant : Alarm will not stop until "STOP" is
pressed or the error is cleared/corrected.
002 STOP COMM.
JRNL
1 = Off
2 = On
Selects whether the machine prompts to print the
COMM. Journal when the printout condition is set to
INC and STOP is pressed during communication.
003 Not Used
004 NUMERIC ID
SET
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts and allows to
set or change the Numeric ID.
005 Not Used
006 ID DISPLAY
1 = Number (Numeric ID)
2 = Chara (Character ID)
Selects the priority of displaying the ID.
007 JNL COLUMN
1 = Preset station name
2 = Received ID
Selects the contents of the ID to display on the
Journal.
008 MONITOR
1 = Off
2 = On
Selects whether the Monitor is ON/OFF for
monitoring fax signals.
(FOR SERVICE USE ONLY)
009 DC LOOP
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back to back
communication test.
010 TX LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the TX signal output level, 0 to -15 dBm in 1
dBm steps. (Refer to Chapter 4.3.)
011 RX LEVEL
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
012 DTMF LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
013 G3 RX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
015
~
016
Not Used
Summary of Contents for Panafax UF-490
Page 2: ...2 ...
Page 15: ...15 1 4 Control Panel For USA and Canada For Other Countries ...
Page 37: ...37 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Page 63: ...63 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Page 65: ...65 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...