124
070 LINE ERROR
1 = 128 lines
2 = 256 lines
3 = 512 lines
4 = 1024 lines
5 = 2048 lines
6 = Off
(will not disconnect line)
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
2. Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
071 TOTAL ERROR
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 CONTINUOUS
ERROR
1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6 or
12 lines in Standard mode. If continuous total error
exceeds this setting, the unit will transmit RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 ERROR
DETECT
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN RECEIVE
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 CODING
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
Selects the coding scheme.
076 Not Used
077 RX JAM
LENGTH
1 = Off (unlimited)
2 = 2 m
3 = 8 m
Selects the maximum length of a received document
that can be printed.
078
079
Not Used
080 DOC. TOP
FEED
-5.0 mm
~
+5.0 mm
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 DOC. END
FEED
-5.0 mm
~
+5.0 mm
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
082 JAM LENGTH
1 = 1 m
2 = 2 m
3 = 8 m
4 = Unlimited
Selects the maximum length of the original that can
be scanned.
083 Not Used
084 LINE AS NO
PAPER
1 = Ring (ring)
2 = Busy (keep line busy)
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out or
the unit cannot receive because of any trouble.
085
086
Not Used
087 DARKER LEVEL 0 = Lightest Contrast
~
15 = Darkest Contrast
Selects the contrast level.
0
←
→
15
Lightest
←
→
Darkest
088 NORMAL LEVEL
089 LIGHTER LEVEL
090
091
Not Used
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Panafax UF-490
Page 2: ...2 ...
Page 15: ...15 1 4 Control Panel For USA and Canada For Other Countries ...
Page 37: ...37 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Page 63: ...63 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Page 65: ...65 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...