Operation of laser marker when emergency stop switch, laser stop input and emergency
stop input are operated.
Safety function
Laser marker operation
Release method
Laser Stop Input on
I/O Terminal *1
CLOSE to OPEN
Laser stop is opened during laser emission
•
Laser Pumping: OFF
•
Internal Shutter: CLOSE
•
Status: Alarm E011
Close Laser Stop and input alarm reset.
Laser stop is opened at non-emitting with
opened shutter
•
Laser Pumping: Hold ON
•
Internal Shutter: CLOSE
•
Status: Warning E811
Close Laser Stop.
Emergency Stop
Input on I/O Terminal
CLOSE to OPEN
•
Laser Pumping: OFF
•
Internal Shutter: CLOSE
•
Status: Alarm E004 *2
Close Emergency Stop and input alarm reset.
Push Emergency stop
switch
•
Laser Pumping: OFF
•
Internal Shutter: CLOSE
•
Status: Alarm E002 *2
Push emergency stop switch and input alarm
reset.
*1 : The operation behavior of Laser Stop Input varies depending on the laser emission ON/OFF status.
(Inputting Emergency Stop Input and Emergency Stop Switch, regardless laser emission ON/OFF status, the laser is
powered OFF and the shutter is closed.)
*2 : Under the test marking mode and closing shutter status (non-emitting status), the error does not occur.
Reference
•
Laser pumping can not be started if Emergency stop switch is pushed or Emergency Stop Input on I/O terminal is
opened.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...