3. For ITF/CODE39/NW-7
Data length : 57-byte (LP-V series), 54-byte (LP-400/LP-W series)
Name
Data
length
[byte]
Description
Remarks
Bar code No.
1
“0”–“7”
Area No.
1
“0”–“9”, “A”–“F”
Specifies which area part is the marking
position of the concatenated marking on
the flying object.
In case of marking static object, specify
“0”.
Code type
2
“00”: CODE39
“01”: ITF
“03”: NW-7
Inversion
1
“0”: Do not invert
“1”: Invert
Check character/
start/stop
character
1
•
For CODE39, ITF
“0”: Check character absence
“1”: Check character presence
•
For NW-7
“A”–“D”: Check character absence
“a”–“d”: Check character presence
•
For CODE39, ITF, specify the
existence of check character.
•
For NW-7, select start and stop
characters from A, B, C and D
and specify the existence of check
character.
Bar code height
7
Model type*
Setting range [mm]
LP-V10
“001.000”–“090.000”
LP-4x0
“001.000”–“110.000”
LP-4x5/LP-V15
“001.000”–“160.000”
LP-4x1/LP-W
“001.000”–“055.000”
Narrow element
5
“0.050”–“1.000” [mm]
Indicates the width of narrow element of
bar and space. Set the larger value than
“Line width” in laser setting screen.
X position
8
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Specifies the center coordinate of the
code.
Y position
8
Tilt angle
7
“-180.00”–“+180.00” [°]
Quiet/
narrow element
W
4
“00.0”–“20.0”
Ratio of quiet width to narrow element
width.
Wide/
narrow element
W
3
“1.8”–“3.4”
Ratio of wide element width to narrow
element width.
Laser power
correction
3
“000”–“200” [%]
•
The correction ratio is calculated
using the value set at the laser setting
as 100%.
•
With LP-400/LP-W series, nothing
should be input in Laser Pulse Cycle
Correction.
Scan speed
correction
3
“005”–“500” [%]
(Laser pulse cycle
correction)
(Only for LP-V
series)
(3)
“050”–“200” [%]
* For the detail of the model type, refer to “Target laser marker” (P.8).
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...