36
Terminal
No.
Name/Description
4) Counter No. to reset (SELECT 2: ON)
Resets the counter value to the initial value when the counter function is used in the selected file.
Set D0 to D7 to specify the counter No. to reset and turn ON SET IN.
In case two or more counter numbers are specified, all counters specified are reset.
Example: When the counter No. 0 to 3 are reset.
Turn ON D0, D1, D2, and D3 which represent the counter No. 0, 1, 2, and 3.
D0 to D7: Counter No. 0 to 7
Terminal
Counter No.
Input
D0
0
ON
D1
1
ON
D2
2
ON
D3
3
ON
D4
4
OFF
D5
5
OFF
D6
6
OFF
D7
7
OFF
5) Data number for Rank /External offset function (SELECT 0: ON)
The rank/external offset function allows to switch the marking characters (rank) or the coordinates (external
offset) using the input terminal D0 to D15. Configure the character or coordinate patterns to the data
number corresponding to D0 to D15 in advance. Specify which pattern you will mark from D0 to D15.
Specify the data number in the binary system as D0 to D15 and turn on SET IN (No. 2).
The data numbers corresponding to D0 to D15 are defined as follows according to the settings.
I/O input condition settings *
Terminal
Data number target
Data number
Rank: 4-bit × 4
D0 to D3
Rank 0
0 to 15
D4 to D7
Rank 1
0 to 15
D8 to D11
Rank 2
0 to 15
D12 to D15
Rank 3
0 to 15
Rank: 8-bit × 2
D0 to D7
Rank 0
0 to 255
D8 to D15
Rank 1
0 to 255
External offset: Lower 4 bits
D0 to D3
External Offset
0 to 15
External offset: Lower 8 bits
D0 to D7
External Offset
0 to 255
* You can also use the rank function together with the external offset function. If you use the same
terminal for both the rank and external offset at this time, the input status will be reflected to the data
number of both functions.
Example: Specify data number 15 when using lower 8 bits
Select “0000 1111”, which represents 15 in a 8-bit binary system, by specifying ON/OFF of D0 to D7 as
shown in the below table. (D0 is the lowest digit number.)
D0 to D7: Data number (the lower 8 bits are used)
Terminal
Data No. (Binary)
Input
D0
1
ON
D1
1
ON
D2
1
ON
D3
1
ON
D4
0
OFF
D5
0
OFF
D6
0
OFF
D7
0
OFF
19
RESERVE: System reservation
Do not connect externally.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...