126
⿎
Step & repeat condition : SRC
Sets the condition of “Step & Repeat” to mark the same marking contents on multiple locations in one file.
•
Setting / Readout data of general condition
Set the step & repeat condition for specified number with the following format:
STX
SRC
Sub
command
[Step & repeat] [Number of row] [Number of column]
[Row step] [Column step] [X offset] [Y offset]
[Counter update at each step]
Max. 39-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of general condition
STX
SRC
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Step & repeat
1
“0”: OFF
“1”: ON
Marking the same data is repeated to
the X or Y axis direction.
Number of row
3
“001”–“100”
(number of row x column < 1000)
The number of repeated marking to Y
direction.
Number of
column
3
The number of repeated marking to X
direction.
Row step
7
Model type*
Setting range [mm]
LP-V10
“000.000”–“090.000”
LP-4x0
“000.000”–“110.000”
LP-4x5/LP-V15
“000.000”–“160.000”
LP-4x1/LP-W
“000.000”–“055.000”
The marking pitch to the Y direction is
specified.
Column step
7
The marking pitch to the X direction is
specified.
X offset
(8)
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Specifies X/Y Offset of the reference
step.
(If both values of X&Y offsets are “0”,
X/Y off setting can be omitted.)
Y offset
(8)
Counter update
at each step
2
“00”: same in all steps
“xy”: counter is activated in each steps
“x” represents how to count if there are
“Mark OFF” part in step & repeat.
“x=1”: skips the counter
(missing number)
“x=2”: not skip the counter
(sequential number)
“y” represents direction for counting order.
“y=0”: from upper left to right
“y=1”: from upper left to bottom
“y=2”: from upper right to left
“y=3”: from upper right to bottom
* For the detail of the model type, refer to “Target laser marker” (P.8).
Reference
•
When the Step and Repeat setting is set to “None”, the Step and Repeat setting can be omitted. If data is input and that
data is out of the setting range, response data for abnormal receiving is returned.
• When the data is readout under the step & repeat is set to “None”, the subsequent fields following to “number of Row” is
not readout.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...