2-3 Connecting I/O Terminal Block
2-3-1 Connecting samples (Independent operation of laser marker)
⿎
Connecting sample for NPN models
[LP-4xx(T)U / LP-4xx(T)U-A / LP-4xxS9(T)U / LP-4xxS9(T)U-A / LP-VxxU / LP-VxxU-A /
LP-W series]
B12: EMER.+
B11: EMER.-
A12: LASER STOP +
A11: LASER STOP -
A4 : TRIG.IN
A2 : IN COM.
A1 : +12V OUT
B2 : OUT COM.
B1 : 0V OUT
To manual door
To emergency stop switch
To sensor
•
Connect A1 [+12V OUT] and A2 [IN COM.], B1 [0V OUT] and B2 [OUT COM.] as I/O power supply for marking.
•
Connect B12 [EMER.+] and B11 [EMER.-] to release the emergency stop function. (Opening between B12 - B11 turns off
the laser pumping and marking is disabled.)
•
Connect A12 [LASER STOP+] and A11 [LASER STOP-] to release the laser stop function. (Opening between A12 - A11
closes the internal shutter, and changes the status of the device into invalid for marking.)
•
The following terminals are short-circuited by a short bar at factory shipment.
A1 [+12V OUT]
―
A2 [IN COM.]
B1 [0V OUT]
―
B2 [OUT COM.]
B12 [EMER.+]
―
B11 [EMER.-]
A12 [LASER STOP+]
―
A11 [LASER STOP-]
Notice
•
Short-circuiting IN COM. and OUT COM. in supplying power might cause the short out and also cause the trouble with
the laser marker.
•
[IN COM.] and [OUT COM.] on the I/O terminal block are connected with [IN COM.] and [OUT COM.] on the I/O
connector respectively and internally. Therefore, inverting the power supply wiring for the I/O terminal block and the I/O
connector might cause a short circuit, resulting in the failure of the laser marker.
•
Please make sure to check the power wiring before running the laser marker.
•
When the laser marker is to be controlled by external power such as PLC, c side of the external power to A2 [IN
COM.] and - side to B2 [OUT COM.]. In this case, do not connect externally to A1 [+12V OUT] and B1 [0V OUT] of I/O
terminal block. (If a short bar is installed, remove it.) For details, refer to “2-3-2 Connecting sample with external devices”
(P.44).
Reference
•
“Output simulation” and “I/O check monitor” can simulate ON/OFF state on each connector. Please use these functions
in checking the wiring. (Refer to the Operation/Maintenance Manual.)
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...