110
⿎
Logo file : CDF
Sets the logo file.
•
Setting / Readout data of logo marking function
STX
CDF
Sub
command
[Log No.] [Log file name]
Variable length
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of logo marking function
STX
CDF
R
[Logo No.]
2-byte
(Check sum)
Delimiter
Name
Data length [byte]
Description
Remarks
Logo No.
2
“00”–“15”
Logo file name
Variable length
The long file name can be
specified. Except the extended
characters, entry of up to 10 shift-
JIS characters or 20 ASCII code
characters is recommended.
The logo file name corresponding to the
specified number is indicated.
The logo file setting will be deleted when no
file name is specified in this command.
• For VEC file, the extension can be
omitted (in this case, the response has
an extension.)
When the file name is “ABCD.VEC”:
“ABCD” or “ABCD.VEC”
• For a DXF file, an extension is required.
When the file name is “ABCD.DXF”:
“ABCD.DXF”.
Reference
• In the case of specifying logo file in VEC format, apply CDC command for setting logo condition, and in the case of
specifying logo file in DXF format, apply CDD command for setting logo condition.
•
If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (2-byte
character), these 2-byte characters are read out in shift-JIS code.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...