157
ERROR
CODE
Error details
Measures
E903
No specified 2D code pattern.
Specify 2D pattern code which has been already
registered.
E910
Existed invalid character for converting into bar code.
Set the character that can be bar coded.
E911
Cannot create bar code.
Use the condition where a barcode can be created.
E912
Too small dimension of narrow element/basic module
width for bar code.
Specify the setting value for the width of the narrow
element/basic module larger than that of the line
width of the laser.
E913
No quiet zone in bar code.
Set the proper value for “Quiet/Narrow Ratio”.
With the inversion setting, set always quiet zone.
E914
Too small separate pattern or composite row height.
•
Adjust the height of one step bar code.
•
Specify the proper value for “Separation Ptrn H/W”
so that the “Separation Pattern Height” becomes
“0” or “Marking Width” is larger than “Separation
Pattern Width”.
Reference
•
When other error not listed in this section was occurred, restart the laser marker.
• If the symptom persists after restart, contact our sales office.
ME-LP400V-EX-6