156
ERROR
CODE
Error details
Measures
E640
Invalid function for combining with flying object.
• With the marking to flying object, do not use the
following functions.
•
Step & repeat
•
Reset at date update function
•
Arbitrary point radiation
•
Overwrite function
• With the equidistant marking to flying object, do
not use the following functions.
•
Rank
•
External offset
•
Serial data marking
• Release flying object marking function with trigger
setting.
E650
Invalid setting of processing element.
Set the distance between start and end points of the
arc smaller than double of radius.
E651
Too short line segment of processing element.
Set the larger value to the length of the line than
width of the line.
E660
Cannot convert dxf file.
• Save the DXF file with DXF-R12J, R13J or R14
format.
•
Delete the entities which are not supported by
laser marker in the DXF file.
• Read the DXF file again to the laser marker.
E690
Cannot finish measurement during specified time.
•
Reduce marking contents and measure marking
time.
•
Speed up scan speed.
E700
Unable to lase as laser pumping is turned OFF.
Turn ON the laser pumping and after the laser
pumping has completed, start marking.
E701
*1
Started laser power check in laser pumping OFF
state.
Turn ON the laser pumping and after the laser
pumping has completed, start power check.
E800
---------------------------
(no message : Invalid input of marking trigger while
Ready is OFF.)
•
Change marking timing so that trigger input is
performed after marking ready output is turned on.
•
Check wiring and control procedure for I/O
terminal, wiring to communication port, and the
procedure of the communication command.
E811
Occurred laser stop from external terminal.
•
Check the wiring of the laser stop input terminal
and contact of the switch.
• Confirm operation logic of connection device.
E900
Existed invalid function character for simultaneous
use.
The following combination of the functions are not
available in one file.
•
Serial data marking function and rank function
•
Serial data marking function and external offset
function
Delete any one of these functions from the file.
E901
Existed invalid character for converting into 2D code.
Set the character that can be converted into 2D code.
E902
Cannot create 2D code.
Use the condition where 2D code can be created.
*1 : Error that may occur for LP-V / LP-W series only.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...