RINGBACK_TONE_GAIN
Value Format
Integer
Description
Specifies the gain, in decibels, of the ringback tone.
Value Range
-24–6
Default Value
0
RINGBACK_TONE_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (0: Infinite time)
Default Value
60,2000,3940
Web User Interface Reference
HOLD_ALARM_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of the hold alarm using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (0: No tone)
Default Value
425
HOLD_ALARM_GAIN
Value Format
Integer
Description
Specifies the gain, in decibels, of the hold alarm.
Value Range
-24–6
Default Value
0
HOLD_ALARM_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of the hold alarm using up to 10
whole numbers (on 1, off 1, on 2, off 2…) separated by commas.
170
Administrator Guide
Document Version 2012-07
Section 5 Configuration File Programming
Summary of Contents for KX-UT670
Page 14: ...14 Administrator Guide Document Version 2012 07 Table of Contents ...
Page 226: ...226 Administrator Guide Document Version 2012 07 Section 8 Backup and Restore ...
Page 230: ...230 Administrator Guide Document Version 2012 07 Section 9 Resetting the Unit ...
Page 236: ...236 Administrator Guide Document Version 2012 07 Section 10 Troubleshooting ...
Page 239: ...Section 12 Appendix Document Version 2012 07 Administrator Guide 239 ...
Page 242: ...242 Administrator Guide Document Version 2012 07 Section 12 Appendix ...
Page 243: ...Index Document Version 2012 07 Administrator Guide 243 ...
Page 249: ...Document Version 2012 07 Administrator Guide 249 Notes ...