11-C-3
Item
Number
Input Value
Assigning Items
Continued
14 : T-1 (T-1 Trunk) card
15 : E-1 (E-1 Trunk) card
16 : AGC (Automatic Gain Control) card
17 : DISA (Direct Inward System Access) card
18 : OPX (Off Premise Extension) card
19 : ATLC (Attendant Console Line Circuit) card
20 : DPH (Doorphone Circuit) card
21 : RMT (Remote Circuit) card
Conditions
If “SLA” command is entered without index number, all physical slot numbers will be
displayed in ascending order (from 101 to 314).
Card assignment and the status
• See Section 1-A-5.00 “Service Cards Description” for cards description.
• See Section 10-C-2.00 “Slot Assignment” for installing the cards in combination.
• When assigning a card, the card status is Out of Service (OUS). When using the
card, the card status should be set to In Service (INS).
For In Service (INS) and Out of Sevice (OUS), refer to Section 9-F-3.00 “In
Service (INS)” and Section 9-F-4.00 “Out of Service (OUS)”.
For confirming whether card status is INS or OUS, refer to Section 16-F-1.02
“Card Status Screen”.
• T-1 and E-1 cards can only be assigned to the odd slot number in each shelf.
• When T-1 or E-1 card is assigned, “
***
” is displayed on the next slot number and
any assignment is impossible.
Relations between this assignment and the other assignments
• If no CO trunk card is assigned, it is not possible to program “CO Line (COL)”.
• If AGC card is not assigned, “Automatic Gain Control (AGC)” cannot be pro-
grammed.
• If DPH card is not assigned, “Doorphone (DPH)” cannot be programmed.
• If ATLC card is not assigned, it is not possible to program “Attendant Console
(ATT)” and “Attendant Queue Priority (AQP)”.
• If DISA card is not assigned, it is not possible to program “DISA (DIS)”, “DISA
Code (DIC)” and “DISA Password (DIP)”.
• If DID card is not assigned, it is not possible to program “DID (DID)”.
When deleting or changing the card assignment
• When deleting or changing the pre-assigned card type, the conditions should be
the followings:
— The card status is OUS or Fault.
— All of the port data has been deleted.
However, if there exist port data, it is possible to change the cards as follows:
— PLC card
HLC card
— SLC card
HLC card
Summary of Contents for KX-TD500
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...Section 1 System Outline ...
Page 10: ......
Page 20: ......
Page 26: ......
Page 32: ......
Page 36: ......
Page 51: ...Section 2 Installation ...
Page 52: ......
Page 56: ......
Page 78: ......
Page 160: ......
Page 173: ...Section 3 System Features and Operation ...
Page 174: ......
Page 178: ......
Page 180: ......
Page 208: ......
Page 218: ......
Page 256: ......
Page 260: ......
Page 361: ...Section 4 Station Features and Operation Proprietary Integrated Telephone System PITS ...
Page 362: ......
Page 376: ...4 A 10 Programmable Feature buttons F1 F2 F3 TRANSFER PF01 PF02 PF03 ...
Page 434: ......
Page 462: ......
Page 492: ......
Page 516: ......
Page 536: ......
Page 576: ......
Page 577: ...Section 5 Station Features and Operation Single Line Telephone SLT ...
Page 578: ......
Page 602: ......
Page 642: ......
Page 656: ......
Page 675: ...Section 6 Station Features and Operation Attendant Console ATT ...
Page 676: ......
Page 680: ......
Page 686: ......
Page 688: ......
Page 728: ......
Page 746: ......
Page 750: ......
Page 768: ......
Page 782: ......
Page 814: ......
Page 816: ......
Page 817: ...Section 7 Manual Vol 2 Overview ...
Page 818: ......
Page 820: ......
Page 822: ......
Page 833: ...Section 8 Preparation for Programming and Maintenance VT220 and Compatibles ...
Page 834: ......
Page 850: ......
Page 860: ......
Page 864: ......
Page 866: ......
Page 868: ......
Page 870: ......
Page 899: ...Section 9 Preparation for Programming and Maintenance Dumb Type Terminal ...
Page 900: ......
Page 914: ......
Page 920: ......
Page 930: ......
Page 931: ...Section 10 System Programming VT220 and Compatibles ...
Page 932: ......
Page 936: ......
Page 938: ......
Page 940: ......
Page 1024: ......
Page 1090: ......
Page 1117: ...Section 11 System Programming Dumb Type Terminal ...
Page 1118: ......
Page 1122: ......
Page 1124: ......
Page 1260: ......
Page 1269: ...Section 12 System Programming Proprietary Integrated Telephone System PITS ...
Page 1270: ......
Page 1272: ......
Page 1274: ......
Page 1302: ......
Page 1303: ...Section 13 Station Programming Proprietary Integrated Telephone System PITS ...
Page 1304: ......
Page 1306: ......
Page 1308: ......
Page 1368: ......
Page 1369: ...Section 14 Station Programming Attendant Console ...
Page 1370: ......
Page 1372: ......
Page 1378: ......
Page 1392: ......
Page 1394: ......
Page 1395: ...Section 15 Maintenance VT220 and Compatibles ...
Page 1396: ......
Page 1400: ......
Page 1402: ......
Page 1406: ......
Page 1418: ......
Page 1476: ......
Page 1495: ...Section 16 Maintenance Dumb Type Terminal ...
Page 1496: ......
Page 1500: ......
Page 1508: ......
Page 1520: ......
Page 1536: ......
Page 1540: ......
Page 1541: ...Section 17 Backup Utility On Site ...
Page 1542: ......
Page 1544: ......
Page 1546: ......
Page 1556: ......
Page 1558: ......
Page 1559: ...Section 18 Backup Utility Remote Location ...
Page 1560: ......
Page 1562: ......
Page 1564: ......
Page 1570: ......
Page 1571: ...Section 19 Abbreviations ...
Page 1572: ......