4.2.3.3 UM Group Failover
Description
Each UM group can be assigned a failover destination. If a call is routed to a UM group that is unavailable, the
call will be redirected to the specified UM group.
PBX
PBX
UM Group 1
Failover Group: 3
UM Group 2
PBX
UM Group 3
Offline
Incoming Call
UM group failover applies to incoming trunk calls (including DISA), intercom calls, and faxes.
Conditions
•
If a call cannot be routed to a UM group and no failover UM group is specified, the system handles the call
according to Intercept Routing—No Destination (
®
2.1.1.7 Intercept Routing—No Destination).
•
Failover redirection does not cascade; if the failover destination is unavailable, the call will not be redirected
to that UM group’s failover destination.
•
The same UM group may be specified as the failover destination for multiple UM groups. For example, UM
group 3 can be the failover destination for both UM group 1 and UM group 2.
PC Programming Manual References
11.7.2 PBX Configuration—[3-7-2] Group—UM Group—Unit Settings—
Fail Over Site Name
Feature Guide
371
4.2.3 One-look Networking Survivability
Summary of Contents for KX-NS1000
Page 14: ...14 Feature Guide Table of Contents...
Page 15: ...Section 1 For Your Safety Feature Guide 15...
Page 18: ...18 Feature Guide 1 1 1 For Your Safety...
Page 19: ...Section 2 Call Handling Features Feature Guide 19...
Page 278: ...278 Feature Guide 2 28 2 Outgoing Message OGM...
Page 279: ...Section 3 Unified Messaging System Feature Guide 279...
Page 335: ...Section 4 Network Features Feature Guide 335...
Page 434: ...434 Feature Guide 4 3 6 Network ICD Group...
Page 435: ...Section 5 System Configuration and Administration Features Feature Guide 435...
Page 521: ...Section 6 Appendix Feature Guide 521...
Page 540: ...540 Feature Guide 6 5 4 PCMPR Software File Version 003 2xxxx...
Page 541: ...Feature Guide 541 Notes...