Read Commands
Item
Command
Data
Description
Format
R
ead
C
om
m
and
Measurement
Value Read
RMD
-
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
2
Read Received
Light Intensity
RID
-
+00000 to
+04095
+00000 to +04095
FORMAT
1
Alarm status
ROA
-
+00000
Alarm OFF
+00001
Measurement Alarm ON
OUT1 Terminal
Read
RZA
-
+00000
OUT1 OFF
+00001
OUT1 ON
OUT2 Terminal
Read
RZB
-
+00000
OUT2 OFF
+00001
OUT2 ON
OUT3 Terminal
Read
RZC
-
+00000
OUT3 OFF
+00001
OUT3 ON
All Outputs
Read
RMB
-
-
Mesured value/Received
light intensity
/OUT1/OUT2/OUT3/AL
FORMAT
3
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.
Buffering Commands
Item
Command
Data
Description
Format
B
uf
fer
ing
C
om
m
and
Buffering Mode
RBD WBD
+00000
Continuous
FORMAT
1
+00001
Trigger
Buffering Rate
RBR WBR
+00001 to
+65535
+00001 to +65535
Accumulated Amount
RBC WBC
+00001 to
+03000
+00001 to +03000
Trigger Point
RTP WTP
+00001 to
+03000
+00001 to +
accumulated amount
Trigger Delay
RTL WTL
+00001 to
+65536
+00000 to +65535
Trigger
Conditions
RTR WTR
+00000
At timing input ON
+00001
At or higher than
threshold
+00002
Lower than threshold
+00003
At an alarm occurred
+00004
At an alarm released
Threshold
RBL WBL
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
2
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...