Displacement Judgment
This function is used to set an upper limit (threshold a), lower limit (threshold
b), and hysteresis for the judgment of measurement values.
Item
Panel display
Setting range
Function
Threshold a
-95000 to +95000
Sets threshold a,
threshold b and
hysteresis.
Threshold b
-95000 to +95000
Hysteresis
0 to +95000
The following default values apply.
Type
Diffuse reflection
Specular reflection
Threshold
a
Threshold
b
Hystere
sis
Threshold
a
Threshold
b
Hystere
sis
30 mm
+4mm
-4mm
8
μm
+2mm
-2mm
8μm
50 mm
+10mm
-10mm
20μm
+5mm
-5mm
20μm
85 mm
+20mm
-20mm
40μm
+10mm
-10mm
40μm
120 mm
+60mm
-60mm
120μm
-
-
-
250 mm
+150mm
-150mm
300
μm
-
-
-
•
Set the value so that |Threshold a - Threshold b| is larger than the hysteresis × 2.
•
The decimal point position varies with each model.
Pressing [▲] for at least 2 seconds will set Threshold a. Also, pressing [▼]
for at least 2 seconds will set Threshold b.
● Setting Procedure
(
Setting Threshold a
)
1
Display the "Output Setting" screen
while the system is in setting mode.
2
Press the [ENTER] key. The "Jud
gment
Output Selection" screen will be displayed.
3
Press the [DOWN] key once. The
"Threshold a" screen will be displayed.
4
Press the [ENTER] key. The present
threshold will be displayed. The leftmost
digit will be selected.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...